• Home
  • Search
  • Calculated attenuation correction for awake small animal brain PET studies
  • Cite Icon12
  • https://doi.org/10.1109/nssmic.2013.6829263Copy DOI Icon

Calculated attenuation correction for awake small animal brain PET studies

  • Oct 1, 2013
  • Georgios I Angelis +7 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Attenuation correction of small animal PET data is very important when quantitative images are of interest. Attenuation correction coefficients are conventionally obtained via a transmission or a computed tomography scan, which require anaesthetisation of the animal. However, in the context of awake and/or freely moving animals, where animal motion is compensated via appropriate motion tracking and correction techniques, anaesthetisation is no longer required. In this work we investigate the accuracy of a transmission-less attenuation correction approach based on the segmentation of the motion corrected emission image. Results on both phantom and real rat data acquired on the microPET Focus220 scanner, indicate good agreement between the segmentation based and conventional transmission based approach (∼ 2% difference). In addition, the segmentation based approach has the potential to eliminate noise propagation from the measured transmission data to the reconstructed attenuation corrected emission images.

Similar Papers
  • Research Article
  • Citations21

Ultra-low dose CT attenuation correction for PET/CT: analysis of sparse view data acquisition and reconstruction algorithms

  • Sep 09, 2015
  • Physics in Medicine & Biology
  • Xue Rui +7
  • Dissertation

Motion correction of PET for improved image quality

  • Jan 17, 2020
  • The University of Queensland
  • Ashley Gavin Gillman
  • Conference Article

A new approach in patient motion correction for cardiac SPECT: A simulation study

  • Oct 01, 2009
  • T Hughes +2
  • PDF
  • Research Article
  • Citations13

Comparison of two elastic motion correction approaches for whole-body PET/CT: motion deblurring vs gate-to-gate motion correction

  • Mar 30, 2020
  • EJNMMI Physics
  • Stefanie Pösse +6
  • Conference Article
  • Citations1

A novel approach to motion correction for ASL images based on brain contours

  • Mar 17, 2015
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Giacomo Tarroni +5
  • Research Article
  • Citations24

Attenuation correction of PET activation studies in the presenceof task-related motion

  • Aug 01, 2003
  • NeuroImage
  • Odile A Van Den Heuvel +4
  • PDF
  • Research Article
  • Citations7

DAcquisition setting optimization and quantitative imaging for 124I studies with the Inveon microPET-CT system

  • Jan 01, 2012
  • EJNMMI Research
  • Nadège Anizan +4
  • Research Article

Quantitative image reconstruction for small-animal SPECT imaging including resolution recovery, scatter correction and attenuation correction.

  • Apr 01, 2026
  • Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
  • Amir Dareyni +7
  • Conference Article

A comparison of CT-based attenuation correction strategies for PET data of moving structures

  • Oct 01, 2008
  • Christian Richter +5
  • Research Article
  • Citations15

Attenuation correction of small animal SPECT images acquired with /sup 125/I-iodorotenone

  • Jun 01, 2006
  • IEEE Transactions on Nuclear Science
  • A.B Hwang +4
  • Conference Article
  • Citations1

Effects of MR-invisible objects and object attenuation on PET quantification in small animal PET/MR imaging

  • Oct 01, 2013
  • Ilja Bezrukov +5
  • Research Article
  • Citations5

Effects of CT-based attenuation correction of rat microSPECT images on relative myocardial perfusion and quantitative tracer uptake.

  • Mar 23, 2015
  • Medical physics
  • Jared H Strydhorst +2
  • PDF
  • Research Article
  • Citations3

Improved PET/MRI accuracy by use of static transmission source in empirically derived hardware attenuation correction

  • Mar 08, 2021
  • EJNMMI Physics
  • Adam Farag +4
  • Conference Article
  • Citations6

Attenuation Correction for Myocardial Perfusion SPECT Imaging in the Image Domain

  • Oct 16, 2021
  • Samaneh Mostafapour +7
  • Research Article
  • Citations16

Development and evaluation of QSPECT open-source software for the iterative reconstruction of SPECT images

  • Jun 01, 2010
  • Nuclear Medicine Communications
  • George K Loudos +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.