• Home
  • Search
  • Novel microscope-integrated stereoscopic display for intrasurgical optical coherence tomography
  • Cite Icon5
  • https://doi.org/10.1117/12.2076406Copy DOI Icon

Novel microscope-integrated stereoscopic display for intrasurgical optical coherence tomography

  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The first generation of intrasurgical optical coherence tomography (OCT) systems displayed OCT data onto a separate computer monitor, requiring surgeons to look away from the surgical microscope. In order to provide real-time OCT feedback without requiring surgeons to look away during surgeries, recent prototype research and commercial intrasurgical OCT systems have integrated heads-up display (HUD) systems into the surgical microscopes to allow the surgeons to access the OCT data and the surgical field through the oculars concurrently. However, all current intrasurgical OCT systems with a HUD are only capable of imaging through one ocular limiting the surgeon’s depth perception of OCT volumes. Stereoscopy is an effective technology to dramatically increase depth perception by presenting an image from slightly different angles to each eye. Conventional stereoscopic HUD use a pair of micro displays which require bulky optics. Several new approaches for HUDs are reported to use only one micro display at the expense of image brightness or increased footprint. Therefore, these techniques for HUD are not suitable to be integrated into microscopes. We have developed a novel stereoscopic HUD which uses spatial multiplexing to project stereo views into both oculars simultaneously with only one micro-display and three optical elements for our microscope-integrated OCT system. Simultaneous stereoscopic views of OCT volumes are computed in real time by GPU-enabled OCT system software. We present, to our knowledge, the first microscope integrated stereoscopic HUD used for intrasurgical OCT with a novel optical design for stereoscopic viewing devices and report on its preliminary use in human vitreoretinal surgeries.

Similar Papers
  • Research Article
  • Citations1

Feasibility of microscope-integrated swept-source optical coherence tomography in canaloplasty.

  • Dec 01, 2020
  • Annals of translational medicine
  • Huan Xu +8
  • Research Article
  • Citations44

Novel microscope-integrated stereoscopic heads-up display for intrasurgical optical coherence tomography.

  • Apr 06, 2016
  • Biomedical Optics Express
  • Liangbo Shen +8
  • Research Article
  • Citations1

Validation and comparison of two commercial OCT systems for in vitro measurement of soft contact lens thickness

  • Jan 01, 2026
  • Journal of Optometry
  • Maria Romaguera +4
  • Research Article

Motion of intracochlear structures measured with a commercial optical coherence tomography (OCT) system

  • May 01, 2017
  • The Journal of the Acoustical Society of America
  • Michael E Ravicz +3
  • Research Article
  • Citations16

Advances in Whole-Eye Optical Coherence Tomography Imaging.

  • Jan 01, 2019
  • Asia-Pacific journal of ophthalmology (Philadelphia, Pa.)
  • Anthony N Kuo +2
  • Research Article
  • Citations26

Evaluation of a Self-Imaging SD-OCT System for Remote Monitoring of Patients with Neovascular Age Related Macular Degeneration.

  • Dec 01, 2020
  • Klinische Monatsblatter fur Augenheilkunde
  • Kester Nahen +2
  • Book Chapter
  • Citations9

Spectral/Fourier Domain Optical Coherence Tomography

  • Jan 01, 2009
  • Royce W S Chen +2
  • PDF
  • Research Article
  • Citations8

Expanding Functionality of Commercial Optical Coherence Tomography Systems by Integrating a Custom Endoscope

  • Sep 29, 2015
  • PLoS ONE
  • Weston A Welge +1
  • Conference Article
  • Citations2

Signal analysis and image simulation for optical coherence tomography (OCT) systems

  • Jul 01, 2014
  • Chandan Singh Rawat +1
  • Research Article
  • Citations49

Optical Coherence Tomography

  • Oct 22, 2012
  • Circulation
  • James M Mccabe +1
  • Research Article
  • Citations57

Visualization and tissue classification of human breast cancer images using ultrahigh-resolution OCT.

  • Mar 01, 2017
  • Lasers in Surgery and Medicine
  • Xinwen Yao +5
  • Research Article
  • Citations1

Factory Built-in Type Simplified OCT System for Industrial Application

  • Jan 01, 2009
  • IEEJ Transactions on Electronics, Information and Systems
  • Tatsuo Shiina +2
  • PDF
  • Research Article
  • Citations5

Spectroscopic optical coherence tomography at 1200nm for lipid detection.

  • Sep 09, 2023
  • Journal of biomedical optics
  • Vivek Kuttippurath +3
  • Conference Article

Motion of organ of Corti structures in the gerbil cochlear apex, measured with a commercial optical coherence tomography (OCT) system

  • Jan 01, 2018
  • AIP conference proceedings
  • Michael E Ravicz +3
  • Conference Article

Miniature spectrometer and beam splitter for an integrated optical coherence tomography system

  • May 01, 2013
  • B I Akca +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.