Abstract

Optical coherence tomography (OCT) is a powerful diagnostic imaging tool with which multiple quantitative and qualitative studies on diseases of the eye have been performed. 1–7 Optical coherence tomography imaging is analogous to ultrasonic imaging, except that it measures echo time delays of light instead of sound. 1 ,8 Because light travels extremely quickly, echo time delays cannot be directly measured, and correlation techniques are required. Using a technique called low-coherence interferometry, a beam of light from a low-coherence light source, such as a superluminescent diode (SLD), is directed through a beam splitter and is divided into a sample and a reference beam. Light from the sample beam is reflected back from retinal structures with different echo time delays, depending on internal properties of ocular structures. Light from the reference beam is reflected from a reference mirror whose distance is known. The echoes from the two arms are combined by an interferometer and detected. Standard OCT systems use time-domain detection, where the position of the reference mirror is mechanically scanned, or adjusted, to produce different time delays for the reference beam echoes. In this way, axial scans (measurements of sample beam light echoes versus depth) may be acquired (Fig. 26.1 ). By scanning the beam of light in the transverse direction, a cross-sectional OCT image, or OCT B-scan, may be obtained. With standard time-domain detection, OCT systems typically acquire 400 axial scans per second. In OCT, image resolution can be considered both axially (along the incident light beam) and transversally (perpendicular to the incident light beam). The axial resolution of the OCT system is governed by the coherence length of the light source, which is inversely proportional to the bandwidth. Commercial OCT systems use low-coherence SLD light sources at near-infrared wavelengths of ~820 nm. The Stratus OCT (Carl Zeiss Meditec, Dublin, CA) uses a bandwidth of ~25 nm and achieves 8to 10-μm axial resolution in tissue. Research prototype ultrahigh resolution OCT systems using broadband light sources can achieve axial resolution of 2 to 3 μm. 9–11 Recent commercially available OCT systems using spectral/Fourier domain detection can achieve 5to 8-μm axial resolution. Transverse resolution is determined by the size of the focused light beam incident on the retina and is independent of bandwidth. Because there is a trade-off between depth of focus and spot size, most commercial OCT systems use a 20μm transverse resolution in order to have adequate depth of focus. Aberrations in the human eye have limited transverse resolution to 10 to 15 μm; recently, however, adaptive optics that compensate for ocular aberrations can achieve transverse resolutions of ~4 μm. At this resolution, individual rods and cones may be visualized. 12–14

Similar Papers
  • Research Article
  • Citations1

Validation and comparison of two commercial OCT systems for in vitro measurement of soft contact lens thickness

  • Jan 01, 2026
  • Journal of Optometry
  • Maria Romaguera +4
  • Research Article
  • Citations57

Visualization and tissue classification of human breast cancer images using ultrahigh-resolution OCT.

  • Mar 01, 2017
  • Lasers in Surgery and Medicine
  • Xinwen Yao +5
  • Research Article

Motion of intracochlear structures measured with a commercial optical coherence tomography (OCT) system

  • May 01, 2017
  • The Journal of the Acoustical Society of America
  • Michael E Ravicz +3
  • Research Article
  • Citations26

Evaluation of a Self-Imaging SD-OCT System for Remote Monitoring of Patients with Neovascular Age Related Macular Degeneration.

  • Dec 01, 2020
  • Klinische Monatsblatter fur Augenheilkunde
  • Kester Nahen +2
  • Research Article
  • Citations187

Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema.

  • May 30, 2008
  • Investigative ophthalmology & visual science
  • Farzin Forooghian +4
  • Abstract

Characterization of dental caries using Optical Coherence Tomography

  • Jan 26, 2005
  • Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology
  • L Otis +3
  • Research Article
  • Citations49

Optical Coherence Tomography

  • Oct 22, 2012
  • Circulation
  • James M Mccabe +1
  • PDF
  • Research Article
  • Citations18

Optical coherence tomography with a 2.8-mm beam diameter and sensorless defocus and astigmatism correction

  • Feb 14, 2017
  • Journal of Biomedical Optics
  • Maddipatla Reddikumar +3
  • PDF
  • Research Article
  • Citations8

Expanding Functionality of Commercial Optical Coherence Tomography Systems by Integrating a Custom Endoscope

  • Sep 29, 2015
  • PLoS ONE
  • Weston A Welge +1
  • Conference Article
  • Citations5

Novel microscope-integrated stereoscopic display for intrasurgical optical coherence tomography

  • Mar 04, 2015
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Liangbo Shen +9
  • Research Article
  • Citations25

Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT

  • May 24, 2011
  • Korean Journal of Ophthalmology : KJO
  • Hyun Jin Shin +1
  • Research Article
  • Citations96

Three-dimensional Imaging of Cystoid Macular Edema in Retinal Vein Occlusion

  • Aug 02, 2007
  • Ophthalmology
  • Noritatsu Yamaike +8
  • Book Chapter

InAs Quantum Dots of Engineered Height for Fabrication of Broadband Superluminescent Diodes

  • Jun 13, 2012
  • S. Haffouz +1
  • Dissertation

Investigation of low coherence interferometry techniques for biomedical applications

  • Jan 01, 2014
  • Tzu Hao Chow
  • Conference Article

Spectral domain optical coherence tomography setup and small artery detection based on it

  • Dec 18, 2019
  • Xiaoyu She +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.