• Home
  • Search
  • Phantom studies for possible dose reduction in CT head procedures
  • Cite Icon9
  • https://doi.org/10.1093/rpd/nch571Copy DOI Icon

Phantom studies for possible dose reduction in CT head procedures

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

This paper presents the results of phantom studies to investigate possible dose reduction in relation to image quality in head examinations. The studies were performed using five single-slice computed tomography (CT) scanners. Beginning from the manufacturer's protocols (i.e. default protocols in the scanner software) for routine head (adult) examinations, the values of kV(p), anode current and time were modified. Low-contrast resolution and spatial resolution were controlled using a Catphan 424 phantom. Radiation dose was checked using a polymethylmethacrylate phantom and a pencil ionisation chamber. It was found that CT dose index may be reduced up to three times with practically no loss of image quality.

Similar Papers
  • Research Article
  • Citations444

CT Dose Index and Patient Dose: They AreNotthe Same Thing

  • May 01, 2011
  • Radiology
  • Cynthia H Mccollough +5
  • PDF
  • Research Article
  • Citations22

A qualitative and quantitative analysis of radiation dose and image quality of computed tomography images using adaptive statistical iterative reconstruction

  • May 01, 2016
  • Journal of Applied Clinical Medical Physics
  • Fahad Ahmed Hussain +4
  • Research Article
  • Citations7

Evaluation of Dose Reduction and Image Quality in Pediatric Multi-Detector CT

  • Jul 15, 2010
  • Journal of the Korean Physical Society
  • Seung-Wan Lee +3
  • Abstract

Comparison of the Dixon and CTDI dose quantification techniques

  • Oct 01, 2017
  • Physica Medica
  • Ahmad Albngali +4
  • Research Article
  • Citations16

MO‐A‐ValB‐01: Tradeoffs in Image Quality and Radiation Dose for CT

  • Jun 01, 2006
  • Medical Physics
  • M Mcnitt‐Gray
  • PDF
  • Research Article
  • Citations4

Radiation dose reduction without degrading image quality during computed tomography examinations: Dosimetry and quality control study

  • Jun 04, 2014
  • International Journal of Cancer Therapy and Oncology
  • George Felix Acquah +4
  • Discussion
  • Citations2

Automatic dose reduction should not mask needs for individual dose reduction.

  • Oct 01, 2004
  • Radiology
  • Jean-François Paul +2
  • Research Article
  • Citations10

Adaptive statistical iterative reconstruction use for radiation dose reduction in pediatric lower-extremity CT: impact on diagnostic image quality.

  • Dec 26, 2017
  • Skeletal Radiology
  • Amisha Shah +5
  • Research Article

SU‐E‐I‐62: Assessing Radiation Dose Reduction and CT Image Optimization Through the Measurement and Analysis of the Detector Quantum Efficiency (DQE) of CT Images Using Different Beam Hardening Filters

  • May 29, 2014
  • Medical Physics
  • J Collier +2
  • Conference Article
  • Citations4

National survey on medical exposure to patients undergoing diagnostic radiology examinations: An initial overview on CT doses at UAE hospitals

  • Feb 01, 2011
  • Jamila Salem Alsuwaidi +7
  • Research Article
  • Citations4

Dose reduction and image quality optimizations in CT of pediatric and adult patients: phantom studies

  • Mar 01, 2014
  • Journal of Instrumentation
  • P -H Jeon +5
  • Research Article
  • Citations9

Dose reduction in spiral CT coronary angiography with dual-source equipment. Part I. A phantom study applying different prospective tube current modulation algorithms

  • Aug 07, 2009
  • La radiologia medica
  • C Martini +10
  • Research Article
  • Citations9

Reducing the radiation dose with the adaptive statistical iterative reconstruction technique for chest CT in adults: a parameter study

  • Apr 05, 2014
  • Chinese Medical Journal
  • Wenyun Liu +4
  • Research Article
  • Citations137

A pragmatic approach to determine the optimal kVp in cone beam CT: balancing contrast-to-noise ratio and radiation dose.

  • Apr 08, 2014
  • Dento maxillo facial radiology
  • R Pauwels +5
  • PDF
  • Research Article
  • Citations48

Balancing Radiation Dose and Image Quality: Clinical Applications of Neck Volume CT

  • Jan 25, 2008
  • American Journal of Neuroradiology
  • M.T Russell +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.