• Home
  • Search
  • SEM based data extraction for model calibration
  • Cite Icon1
  • https://doi.org/10.1117/12.707353Copy DOI Icon

SEM based data extraction for model calibration

  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

The model calibration process, in a resolution enhancement technique (RET) flow, is one of the most critical steps towards building an accurate OPC recipe. RET simulation platforms use models for predicting latent images in the wafer due to exposure of different design layouts. Accurate models can precisely capture the proximity effects for the lithographic process and help RET engineers build the proper recipes to obtain high yield. To calibrate OPC models, test geometries are created and exposed through the lithography environment that we want to model, and metrology data are collected for these geometries. This data is then used to tune or calibrate the model parameters. Metrology tools usually provide critical dimension (CD) data and not edge placement error (EPE - the displacement between the polygon and resist edge) data however model calibration requires EPE data for simulation. To work around this problem, only symmetrical geometries are used since, having this constraint, EPE can be easily extracted from CD measurements. In real designs, it is more likely to encounter asymmetrical structures as well as complex 2D structures that cannot easily be made symmetrical, especially when we talk about technology nodes for 65nm and beyond. The absence of 2D and asymmetric test structures in the calibration process would require models to interpolate or extrapolate the EPE's for these structures in a real design. In this paper we present an approach to extract the EPE information from both SEM images and contours extracted by the metrology tools for structures on test wafers, and directly use them in the calibration of a 55nm poly process. These new EPE structures would now mimic the complexity of real 2D designs. Each of these structures can be individually weighed according to the data variance. Model accuracy is then compared to the conventional method of calibration using symmetrical data only. The paper also illustrates the ability of the new flow to extract more accurate measurement out of wafer data that are more immune to errors compared to the conventional method.

Similar Papers
  • Conference Article
  • Citations3

Massive metrology using fast e-beam technology improves OPC model accuracy by >2x at faster turnaround time

  • Mar 22, 2018
  • Qian Zhao +25
  • Research Article
  • Citations4

In-line Critical Dimension Measurement System Development of LCD Pattern Proposed by Newly Developed Edge Detection Algorithm

  • Oct 25, 2013
  • Journal of the Optical Society of Korea
  • Sung-Hoon Park +2
  • Conference Article
  • Citations32

Evaluation of OPC quality using automated edge placement error measurement with CD-SEM

  • Mar 10, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Cyrus Tabery +3
  • Conference Article
  • Citations1

Final CD control through slope/sidewall angle correlation with stepper defocus and electrical parametric

  • Apr 20, 2001
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Robert L Campbell +4
  • Conference Article

Area measurements for simulation-based dispositioning of masks

  • Oct 21, 2005
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Gerard Luk-Pat +3
  • Conference Article
  • Citations6

Automated CD measurements with the Hitachi S-6280

  • May 22, 1995
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Elizabeth E Chain +1
  • Conference Article
  • Citations9

Fast and simple modeling of non-rectangular transistors

  • Oct 24, 2008
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Jen-Yi Wuu +2
  • Conference Article
  • Citations23

A new matching engine between design layout and SEM image of semiconductor device

  • May 10, 2005
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Hidetoshi Morokuma +5
  • Conference Article
  • Citations20

Performance Driven OPC for Mask Cost Reduction

  • Mar 21, 2005
  • P Gupta +3
  • Research Article
  • Citations19

SRAF Insertion via Supervised Dictionary Learning

  • Oct 03, 2019
  • IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
  • Hao Geng +5
  • Conference Article
  • Citations1

Multi-shaped beam data preparation

  • Feb 03, 2010
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • U Weidenmueller +4
  • Conference Article

Mask process correction method comparison and study: CD-SEM box versus standard correction method

  • Oct 16, 2017
  • Mingjing Tian +9
  • Conference Article
  • Citations6

A Practical Method For Edge Detection And Focusing For Linewidth Measurements On Wafers

  • Jul 23, 1985
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Diana Nyyssonen
  • Conference Article
  • Citations1

Massive metrology and failure identification for DRAM applications (Conference Presentation)

  • Mar 26, 2019
  • Harm Dillen +14
  • Conference Article
  • Citations65

Hotspot detection on post-OPC layout using full-chip simulation-based verification tool: a case study with aerial image simulation

  • Dec 15, 2003
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Juhwan Kim +1