Sparse-sampling computed tomography for pulmonary imaging

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

Computed tomography (CT) is a valuable imaging modality for pulmonary imaging. Fast acquisition times and sharp cross-sectional images guarantee high diagnostic confidence. With the introduction of low-dose CT, it has been established as standard for lung screening of heavy smokers in many countries around the world. However, at some point the limits for dose reduction with conventional CT are reached and further reduction would suffer from poor image quality. Sparsesampling CT is one technology that would allow a further radiation dose reduction by reducing the number of acquired projection images. Recently, the feasibility of a fast pulsing X-ray tube for CT has been demonstrated, indicating that sparse sampling could become available in future generations of CT scanners. Therefore, we investigated the effect of sparse sampling by a stepwise reduction of the projection images. A lung phantom with synthetic pulmonary nodules was scanned with a clinical CT system. Sparse sampling was simulated by removing projection images prior to reconstruction. The phantom was scanned at the iso-center and at the highest possible table position (off-center). The modulation transfer function (MTF) was determined for different degrees of sparse sampling. Image quality was evaluated by comparing the reduced dose simulations against the full dose image using the structural similarity index (SSIM). MTF was stable down to using 1/4th of the projection images (4-times sparse sampling, SpS-4) with high degradation at the off-center position (full sampling (FS) 10% MTF, iso-center: 0.64; off-center: 0.47). SSIM indicates a small image quality degradation of FS images compared to sparse-sampling images at low radiation doses at the iso-center (35 mAs; FS: 0.91; SpS-4: 0.93) and stronger degradations at the off-center position (35 mAs; FS: 0.65; SpS-4: 0.84). In conclusion, sparse sampling provides stable MTF results down to 1/4th of the projection images. At low dose levels (iso-center: ≤43 mAs; off-center: ≤86 mAs), sparse sampling performs better in terms of SSIM compared to FS.

Similar Papers
  • Research Article
  • Citations5

Usefulness of the spectral shaping dual-source computed tomography imaging technique in posterior corrective fusion for adolescent idiopathic scoliosis.

  • Jan 17, 2024
  • European Spine Journal
  • Yoshiyuki Noto +6
  • Research Article
  • Citations20

Usefulness of spectral computed tomography for evaluation of intestinal activity and severity in ileocolonic Crohn's disease.

  • Sep 26, 2016
  • Therapeutic Advances in Gastroenterology
  • Jiang Chen Peng +6
  • Abstract

OA158] Noise equivalent number of quanta (NEQ): A tool for choosing the optimal reconstruction algorithm in computed tomography (CT)

  • Aug 01, 2018
  • Physica Medica
  • Vittorio Di Trapani +1
  • Research Article
  • Citations27

Liver volume assessment by conventional vs. helical CT.

  • May 01, 1995
  • Abdominal imaging
  • J Stapakis +3
  • Research Article
  • Citations6

Time-delayed summation as a means of improving resolution on fast rotating computed tomography systems

  • Apr 03, 2012
  • Medical Physics
  • Tristan Nowak +6
  • Research Article
  • Citations22

A streak artifact reduction algorithm in sparse-view CT using a self-supervised neural representation.

  • Aug 08, 2022
  • Medical Physics
  • Byeongjoon Kim +2
  • Research Article
  • Citations25

Validation of synthesized normal-resolution image data generated from high-resolution acquisitions on a commercial CT scanner.

  • Aug 05, 2020
  • Medical Physics
  • Andrew M Hernandez +8
  • Abstract

Patient dose estimation in cardiac computed tomography with a 320 detector row scanner based on Monte Carlo simulation

  • Jan 01, 2014
  • Physica Medica
  • M Cros +6
  • Conference Article
  • Citations9

Characterization of a prototype tabletop x-ray CT breast imaging system

  • Mar 08, 2007
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • J Michael O'Connor +4
  • Research Article

Evaluation of a CZT-based photon-counting detector CT prototype for low-dose lung cancer screening using patient-specific lung phantoms

  • Dec 31, 2025
  • medRxiv
  • Kai Mei +10
  • PDF
  • Research Article
  • Citations14

Improvement in CT image resolution due to the use of focal spot deflection and increased sampling

  • May 01, 2016
  • Journal of Applied Clinical Medical Physics
  • Nicholas Rubert +2
  • Research Article
  • Citations46

Deep learning-based image quality improvement for low-dose computed tomography simulation in radiation therapy.

  • Oct 24, 2019
  • Journal of Medical Imaging
  • Tonghe Wang +9
  • Research Article
  • Citations10

Statistical model based iterative reconstruction in clinical CT systems. Part III. Task-based kV/mAs optimization for radiation dose reduction.

  • Aug 13, 2015
  • Medical physics
  • Ke Li +5
  • Research Article
  • Citations174

Helical CT for nephrolithiasis and ureterolithiasis: comparison of conventional and reduced radiation-dose techniques.

  • Oct 02, 2003
  • Radiology
  • Joan P Heneghan +5
  • Research Article
  • Citations15

A Methodology to Train a Convolutional Neural Network-Based Low-Dose CT Denoiser With an Accurate Image Domain Noise Insertion Technique

  • Jan 01, 2022
  • IEEE Access
  • Byeongjoon Kim +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.