• Home
  • Search
  • Three-dimensional optical coherence tomography employing a 2-axis microelectromechanical scanning mirror
  • Open Access IconOpen Access
  • Cite Icon46
  • https://doi.org/10.1109/jstqe.2005.857683Copy DOI Icon

Three-dimensional optical coherence tomography employing a 2-axis microelectromechanical scanning mirror

Show More
  • Abstract
  • Highlights & Summary
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

We present a three-dimensional (3-D) optical coherence tomography (OCT) system based on a dual axis microelectromechanical system (MEMS) mirror. The MEMS mirror provides high-speed, high resolution 2-axis scanning while occupying a very small volume with extremely low power consumption. The dimensions of the mirror are 600 × 600 μm, and both axes are capable of scanning up to 30 degree angles at frequencies greater than 3 kHz with good linearity. A 3-D image set is acquired when the MEMS mirror is integrated with the fiber-based OCT system. Via 2-axis lateral scanning, combined with an axial scan, a volume (2 × 2 × 1.4 mm) image of tissue, including a cancerous region, from a hamster cheek pouch was obtained. Using a signal processing technique, image data is normally presented by 3-volume showing views at arbitrary angles and locations. The objective of this work is to show the capabilities of a 3-D OCT system utilizing a MEMS scanner as this technology can readily by applied to realize OCT beam delivery systems such as hand held scanners and endoscopic probes. A MEMS based 3-D OCT system employing a high speed, small volume scanner may have the potential to expand the application area of OCT and revolutionize areas of clinical medicine as well as medical research. © 2005 IEEE.

Loading PDF

Similar Papers
  • Conference Article

Three-dimensional time and Fourier domain endoscopic OCT using 2-axis scanning MEMS mirror

  • Feb 09, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Woonggyu Jung +5
  • Conference Article
  • Citations9

Optical coherence tomography based on high-speed scanning MEMS mirror

  • Apr 13, 2005
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Woonggyu Jung +4
  • PDF
  • Research Article
  • Citations122

Three-dimensional endoscopic optical coherence tomography by use of a two-axis microelectromechanical scanning mirror

  • Apr 17, 2006
  • Applied Physics Letters
  • Woonggyu Jung +5
  • Conference Article
  • Citations1

Optical coherence tomography system using a micro-mirror

  • Dec 29, 2010
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Prashanth R +1
  • Conference Article
  • Citations4

Realization of fiber-based OCT system with broadband photonic crystal fiber coupler

  • Feb 09, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Seon Young Ryu +5
  • Dissertation

Investigation of low coherence interferometry techniques for biomedical applications

  • Jan 01, 2014
  • Tzu Hao Chow
  • Research Article

Optical coherence tomography guided cystoscopy in diagnosis and management of clinical bladder tumors

  • Jun 20, 2007
  • Journal of Clinical Oncology
  • C S Lee +5
  • Research Article
  • Citations16

A novel triangular stereo model for 3D reconstruction of uniaxial MEMS-based structured light system

  • Apr 06, 2023
  • Optics and Lasers in Engineering
  • Yuping Ye +4
  • Research Article
  • Citations49

Optical Coherence Tomography

  • Oct 22, 2012
  • Circulation
  • James M Mccabe +1
  • Conference Article
  • Citations2

Signal analysis and image simulation for optical coherence tomography (OCT) systems

  • Jul 01, 2014
  • Chandan Singh Rawat +1
  • PDF
  • Conference Article
  • Citations3

High-speed three-dimensional endoscopic OCT using MEMS technology

  • Jan 20, 2007
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Zhongping Chen +7
  • Conference Article
  • Citations15

High-speed imaging of retinal pathology using ultrahigh-resolution spectral/Fourier domain optical coherence tomography in the ophthalmology clinic

  • Apr 13, 2005
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Tony Ko +5
  • Research Article
  • Citations1

Validation and comparison of two commercial OCT systems for in vitro measurement of soft contact lens thickness

  • Jan 01, 2026
  • Journal of Optometry
  • Maria Romaguera +4
  • Conference Article
  • Citations7

Submicrosecond speed optical coherence tomography system design and analysis using acousto-optics

  • Jun 14, 2002
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Nabeel A Riza +1
  • Research Article
  • Citations10

Submicrosecond speed optical coherence tomography system design and analysis by use of acousto-optics.

  • Jun 01, 2003
  • Applied optics
  • Nabeel A Riza +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.