A novel high-speed no-moving-parts optical coherence tomography (OCT) system is introduced that acquires sample data at less than a microsecond per data point sampling rate. The basic principle of the proposed OCT system relies on use of an acousto-optic deflector. This OCT system has the attractive features of an acousto-optic scanning heterodyne interferometer coupled with an acousto-optic (AO) variable optical delay line operating in a reflective mode. Fundamentally, OCT systems use a broadband light source for high axial resolution inside the sample or living tissue under examination. Inherently, AO devices are Bragg-mode wavelength-sensitive elements. We identify that two beams generated by a Bragg cell naturally have unbalanced and inverse spectrums with respect to each other. This mismatch in spectrums in turn violates the ideal autocorrelation condition for a high signal-to-noise ratio broadband interferometric sensor such as OCT. We solve this fundamental limitation of Bragg cell use for OCT by deploying a new interferometric architecture where the two interfering beams have the same power spectral profile over the bandwidth of the broadband source. With the proposed AO based system, high (e.g., megahertz) intermediate frequency can be generated for low 1/f noise heterodyne detection. System issues such as resolution, number of axial scans, and delay-path selection time are addressed. Experiments described demonstrate our high-speed acousto-optically tuned OCT system where optical delay lines can be selected at submicrosecond speeds.

Similar Papers
  • Conference Article
  • Citations7

Submicrosecond speed optical coherence tomography system design and analysis using acousto-optics

  • Jun 14, 2002
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Nabeel A Riza +1
  • Conference Article
  • Citations2

Signal analysis and image simulation for optical coherence tomography (OCT) systems

  • Jul 01, 2014
  • Chandan Singh Rawat +1
  • Research Article
  • Citations49

Optical Coherence Tomography

  • Oct 22, 2012
  • Circulation
  • James M Mccabe +1
  • Research Article
  • Citations1

Validation and comparison of two commercial OCT systems for in vitro measurement of soft contact lens thickness

  • Jan 01, 2026
  • Journal of Optometry
  • Maria Romaguera +4
  • Research Article
  • Citations187

Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema.

  • May 30, 2008
  • Investigative ophthalmology & visual science
  • Farzin Forooghian +4
  • Conference Article
  • Citations5

Novel microscope-integrated stereoscopic display for intrasurgical optical coherence tomography

  • Mar 04, 2015
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Liangbo Shen +9
  • Conference Article
  • Citations4

Realization of fiber-based OCT system with broadband photonic crystal fiber coupler

  • Feb 09, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Seon Young Ryu +5
  • Research Article
  • Citations16

Repeatability and Reproducibility of Axial and Lateral Measurements on Handheld Optical Coherence Tomography Systems Compared with Tabletop System

  • Oct 21, 2020
  • Translational Vision Science & Technology
  • Xi Chen +11
  • Conference Article
  • Citations7

<title>High-speed no-moving-parts optical coherence tomography system</title>

  • Nov 22, 2000
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Nabeel A Riza +1
  • Dissertation

Investigation of low coherence interferometry techniques for biomedical applications

  • Jan 01, 2014
  • Tzu Hao Chow
  • Conference Article

Optical coherence tomography with a structure of the spatial heterodyne spectrometer

  • Aug 21, 2020
  • Shuyuan Zhu +4
  • Conference Article
  • Citations1

All-fiber common-path fourier-domain optical coherence tomography moving 2-axis based on active surface tracking algorithm

  • Sep 01, 2011
  • C G Song +5
  • PDF
  • Research Article
  • Citations46

Three-dimensional optical coherence tomography employing a 2-axis microelectromechanical scanning mirror

  • Jul 01, 2005
  • IEEE Journal of Selected Topics in Quantum Electronics
  • Woonggyu Jung +6
  • Conference Article
  • Citations5

Novel approach to modeling spectral-domain optical coherence tomography with Monte Carlo method

  • May 01, 2014
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Maciej Kraszewski +4
  • Conference Article
  • Citations15

High-speed imaging of retinal pathology using ultrahigh-resolution spectral/Fourier domain optical coherence tomography in the ophthalmology clinic

  • Apr 13, 2005
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Tony Ko +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.