• Home
  • Search
  • Optical coherence tomography with a structure of the spatial heterodyne spectrometer
  • https://doi.org/10.1117/12.2567938Copy DOI Icon

Optical coherence tomography with a structure of the spatial heterodyne spectrometer

  • Aug 21, 2020
  • Shuyuan Zhu +4 more
Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

In this study, we describe a simple method to produce signals which can reveal the cross-sectional information of samples in an optical coherence tomography (OCT) system. Instead of using the spectrometer and the Fourier transformation calculation in the conventional spectrum domain (SD) OCT system, we use a Mach-Zehnder interferometer structure of the spatial heterodyne spectrometer. In a spatial heterodyne spectrometer, because each position on the photodetector array could be mapped to a specific optical path difference, the spectral density distribution could be retrieved with Fourier transformation. And in an SD-OCT system, cross-section signals are obtained by conducting Fourier transformation to the spectrum signals. Therefore, in our OCT system, the spatial signals captured by the photodetector array is related to the cross-sectional signals obtained in an SD-OCT system. The theoretical study and the numerical simulation demonstrate that by applying our method in an OCT system, the heterodyne spectrometer structure could generate a symmetrical pattern composed of fringes with high spatial frequency. Then the photodetector array captures the pattern to generate a spatial signal. The spatial ordinate of this signal is linearly related to the optical depth in sample, while the amplitude of the signal intensity variation is linearly related to the intensity of coherent backscattered light in the sample. The imaging depth is theoretically unlimited. Also, because of the high spatial frequency of the signal, we further adjust the inclination angle in the heterodyne spectrometer structure to visualize the signal.

Similar Papers
  • Dissertation

Investigation of low coherence interferometry techniques for biomedical applications

  • Jan 01, 2014
  • Tzu Hao Chow
  • Research Article
  • Citations49

Optical Coherence Tomography

  • Oct 22, 2012
  • Circulation
  • James M Mccabe +1
  • Conference Article
  • Citations15

High-speed imaging of retinal pathology using ultrahigh-resolution spectral/Fourier domain optical coherence tomography in the ophthalmology clinic

  • Apr 13, 2005
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Tony Ko +5
  • Conference Article

Three-dimensional time and Fourier domain endoscopic OCT using 2-axis scanning MEMS mirror

  • Feb 09, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Woonggyu Jung +5
  • Conference Article
  • Citations2

Signal analysis and image simulation for optical coherence tomography (OCT) systems

  • Jul 01, 2014
  • Chandan Singh Rawat +1
  • Research Article
  • Citations1

Validation and comparison of two commercial OCT systems for in vitro measurement of soft contact lens thickness

  • Jan 01, 2026
  • Journal of Optometry
  • Maria Romaguera +4
  • Research Article
  • Citations187

Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema.

  • May 30, 2008
  • Investigative ophthalmology & visual science
  • Farzin Forooghian +4
  • Research Article
  • Citations24

Comparison of retinal nerve fibre layer measurements from time domain and spectral domain optical coherence tomography systems

  • Oct 01, 2009
  • Canadian Journal of Ophthalmology
  • Davin E Johnson +3
  • Conference Article
  • Citations7

Submicrosecond speed optical coherence tomography system design and analysis using acousto-optics

  • Jun 14, 2002
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Nabeel A Riza +1
  • Research Article
  • Citations10

Submicrosecond speed optical coherence tomography system design and analysis by use of acousto-optics.

  • Jun 01, 2003
  • Applied optics
  • Nabeel A Riza +1
  • Conference Article
  • Citations4

Realization of fiber-based OCT system with broadband photonic crystal fiber coupler

  • Feb 09, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Seon Young Ryu +5
  • Conference Article
  • Citations5

Novel microscope-integrated stereoscopic display for intrasurgical optical coherence tomography

  • Mar 04, 2015
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Liangbo Shen +9
  • Research Article
  • Citations16

Repeatability and Reproducibility of Axial and Lateral Measurements on Handheld Optical Coherence Tomography Systems Compared with Tabletop System

  • Oct 21, 2020
  • Translational Vision Science & Technology
  • Xi Chen +11
  • Conference Article
  • Citations1

All-fiber common-path fourier-domain optical coherence tomography moving 2-axis based on active surface tracking algorithm

  • Sep 01, 2011
  • C G Song +5
  • PDF
  • Research Article
  • Citations46

Three-dimensional optical coherence tomography employing a 2-axis microelectromechanical scanning mirror

  • Jul 01, 2005
  • IEEE Journal of Selected Topics in Quantum Electronics
  • Woonggyu Jung +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.