• Home
  • Search
  • Noise in scanning capacitance microscopy measurements
  • Cite Icon16
  • https://doi.org/10.1116/1.591476Copy DOI Icon

Noise in scanning capacitance microscopy measurements

  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Scanning capacitance microscopy (SCM) is a powerful tool for two-dimensional (2D) dopant/carrier profiling. Currently noise limits the accuracy of 2D dopant profiles obtained by SCM. In an effort to reduce noise, a systematic analysis of different SCM noise sources is provided. The main noise sources during SCM measurements are capacitance sensor noise and oxide–semiconductor surface induced noise. For adequate tip size, the dominant noise in SCM measurements is caused by variations in the quality of surface. On as-polished surfaces, nonstationary noise is observed. This noise is likely caused by the variations in the density of oxide traps. Tip induced charging of these traps and local variations or fluctuations in discharge time during SCM imaging cause the noise level and noise pattern to be different from image to image. Heat treatment under ultraviolet irradiation or in a hydrogen ambient is found to be an effective way to reduce or even eliminate this type of SCM noise. Stationary surface noise is mostly created by the variations in the oxide thickness. This type of noise correlates with topographic roughness and is very consistent during SCM measurements. By reducing the topographic roughness, the stationary surface noise may be reduced to the level of ∼10−2 of the depletion SCM signal for typical experimental conditions. It is shown that the capacitance sensor noise depends on the capacitance sensor tuning parameters and under proper conditions can be reduced to a negligible level for standard probe tips used in SCM measurements.

Similar Papers
  • Research Article
  • Citations14

Towards reproducible scanning capacitance microscope image interpretation

  • Jan 01, 2004
  • Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
  • J J Kopanski +4
  • Research Article
  • Citations7

Local mapping of interface traps in HfSiO/Si structure by scanning capacitance microscopy using dV/dC signal

  • May 01, 2009
  • Journal of Applied Physics
  • Shingo Kuge +1
  • Research Article
  • Citations39

Observation of metal–oxide–semiconductor transistor operation using scanning capacitance microscopy

  • Oct 11, 1999
  • Applied Physics Letters
  • C Y Nakakura +4
  • Research Article
  • Citations22

Imaging mechanism and effects of adsorbed water in contact-type scanning capacitance microscopy

  • Mar 01, 1996
  • Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
  • Nobuyuki Nakagiri +3
  • Research Article
  • Citations3

Microscopic C-V measurements of SOI wafers by scanning capacitance microscopy

  • Jul 01, 2004
  • The European Physical Journal Applied Physics
  • T Ishida +2
  • Research Article
  • Citations74

Quantitative two-dimensional dopant profile measurement and inverse modeling by scanning capacitance microscopy

  • Jan 16, 1995
  • Applied Physics Letters
  • Y Huang +2
  • Research Article
  • Citations22

Scanning capacitance microscopy measurements using diamond-coated probes

  • May 01, 2002
  • Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
  • Hidehiko Yabuhara +2
  • Research Article

Effect of surface oxide characteristics on Scanning Capacitance Microscopy Imaging

  • Aug 01, 1999
  • Microscopy and Microanalysis
  • Atul A Konkar +2
  • Research Article
  • Citations2

Phosphorus deactivation by hydrogen on hot carrier stressed high-voltage N-channel field effect transistor CMOS device demonstrated by scanning capacitance microscopy imaging

  • Jun 07, 2023
  • Journal of Vacuum Science & Technology B
  • Jochonia Nxumalo +3
  • Research Article
  • Citations6

Electrical current at micro-/macro-scale of undoped and nitrogen-doped MWPECVD diamond films

  • Jul 22, 2017
  • Applied Surface Science
  • G Cicala +4
  • Research Article
  • Citations2

Analysis of the Electrical Activation of P<sup>+</sup> Implanted Layers as a Function of the Heating Rate of the Annealing Process

  • Sep 15, 2007
  • Materials Science Forum
  • Mariaconcetta Canino +6
  • Conference Article
  • Citations1

Modeling the transfer characteristic and harmonic distortion effects in scanning capacitance microscopy measurements

  • May 21, 2001
  • M Ciappa +4
  • Research Article
  • Citations7

Correlation between Fe–Zn Interdiffusion Observed by Scanning Capacitance Microscopy and Device Characteristics of Electro-Absorption Modulators

  • Apr 01, 2003
  • Japanese Journal of Applied Physics
  • Matsuyuki Ogasawara +4
  • Research Article

Analysis and hygienic evaluation of noise burden in public education organizations in Saransk

  • Nov 26, 2020
  • Russian Pediatric Journal
  • O P Balykova +4
  • Book Chapter
  • Citations13

Airframe Noise – High Lift Device Noise

  • Dec 15, 2010
  • Encyclopedia of Aerospace Engineering
  • Xin Zhang
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.