The term “Total Power Factor” defined as the ratio between the active power and the apparent power (consisting of active, reactive and distortion power) of an electrical system has been used for years to describe how good an electrical supply system is utilized. To a single-phase system, it is well defined. To a balanced three-phase supply system, there is no problem in evaluating it because any voltage between two lines and any line-current could be used to find out the apparent power. To an unbalanced three-phase supply without a neutral wire, like that fed to a modern variable voltage variable frequency lift drive, an issue has arisen. This issue was raised by the first author of this article some 16 years ago. The active power can always be accurately measured by the famous “two-wattmeter method” but which line-voltage and which line-current should be chosen to estimate the apparent power becomes a big issue. The issue is now considered significant, because it was recently required in the mandatory Building Energy Code enforced in Hong Kong. In this article, various existing definitions have been studied and a couple of new definitions have been proposed. Based on cases of computer simulation, one final recommendation has been made, which is simple, straight forward, practical for use on-site and reasonable. It is hoped that this article could solve the problem raised by the first author published in year 2000 in BSER&T and practitioners may find it easy to implement this new definition. It is agreed that such a problem is mainly faced by the Building Energy Code assessors in Hong Kong. Practical application: The measurement of total power factor is a statutory requirement in Hong Kong and is a useful parameter used around the world. Based on site measurements, it is an inherent fact that the currents of the three phase lift systems are not perfectly balanced, whereas the voltages are more or less balanced. And owing to the absence of a neutral wire of the three phase supply to a lift system, it is impossible to measure such total power factor by using the conventional definition. If a neutral wire exists, it is not a problem anymore as the total power factor of each phase can be independently measured. Various definitions have been reviewed and one new definition is suggested that could solve this problem. Lift engineers could easily do the job by adopting this new definition, which is verified by simulation and site measurement.

Similar Papers
  • Research Article
  • Citations6

COMPONENTS OF TOTAL ELECTRIC ENERGY LOSSES POWER IN PQR SPATIAL COORDINATES

  • May 18, 2016
  • Electrical Engineering & Electromechanics
  • George G Zhemerov +1
  • Research Article

ANALYSIS OF TRANSIENT STATES IN THE POWER SUPPLY SYSTEM FOR SELECTED INDUSTRIAL ROBOT

  • Jun 30, 2025
  • Journal of Casting & Materials Engineering
  • Sebastian Nowocień +1
  • Conference Article
  • Citations21

Effects of harmonic distortion on the active and reactive power measurements in the time domain: a single phase system

  • Sep 10, 2001
  • S.A Soliman +3
  • Research Article
  • Citations153

A new scheme for generating and measuring active, reactive, and apparent power at power frequencies with uncertainties of 2.5×10/sup -6/

  • Apr 01, 1999
  • IEEE Transactions on Instrumentation and Measurement
  • G Ramm +2
  • Book Chapter
  • Citations8

Principles of Electrical Power Control

  • Jan 01, 2008
  • Zbigniew Hanzelka +1
  • PDF
  • Research Article
  • Citations1

THE EFFECT OF VARIATION OF NONLINEAR LOAD ON POWER FACTOR OF THE AC SUPPLY NETWORK

  • Jun 01, 2010
  • Journal of Engineering
  • Mohammed Abdulla Abdulsada +2
  • Research Article

Automatic Power Factor Compensation

  • Apr 09, 2023
  • International Journal of Advanced Research in Science, Communication and Technology
  • Prof Sarang V Bhonde +6
  • Conference Article

Monitoring of power consumprion in systems of electrical supply

  • Jun 26, 2004
  • Proceedings. The 8th Russian-Korean International Symposium on Science and Technology, 2004. KORUS 2004.
  • M.A Gnatenko +4
  • Research Article
  • Citations105

Improved Power Quality Switched Inductor Cuk Converter for Battery Charging Applications

  • Nov 01, 2018
  • IEEE Transactions on Power Electronics
  • B R Ananthapadmanabha +2
  • Conference Article
  • Citations6

Dynamic Response Improvement of a Three-Phase Line Interactive UPS System with Active Power Line Conditioning

  • Jan 01, 2007
  • Sergio Augusto Oliveira Da Silva +2
  • Research Article
  • Citations43

An improved three-phase digital recorder system for calibrating power instrumentation

  • Apr 01, 1997
  • IEEE Transactions on Instrumentation and Measurement
  • R Arseneau +2
  • Conference Article
  • Citations16

Development of Active Power Factor Correction controller using boost converter

  • Dec 01, 2016
  • Sujata Powniker +1
  • Conference Article
  • Citations1

Design of A Power Quality Monitoring System Based on MSP430

  • Jan 01, 2013
  • Qiang Wang +3
  • Research Article
  • Citations33

Measurement of AC electric power based on dual transverse Pockels effect

  • Jan 01, 2001
  • IEEE Transactions on Instrumentation and Measurement
  • Changsheng Li +2
  • Research Article
  • Citations1

Development of dual access energy monitoring for the smart control system

  • Mar 24, 2022
  • Journal of Ambient Intelligence and Smart Environments
  • Shubham Devidas Gujar +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.